The NicheLite for STR91x product includes the InterNiche Nichelite TCP/IP Stack, HTTP Server, FTP Server, and TFTP Server and Client. The target platform is the STR910-Eval board from ST Microelectronics.
Refer to the "STR910-EVAL Evaluation Board User Manual" from ST Microelectronics (UM0174) for information regarding how to properly configure and cable the board. The NicheLite software uses the Ethernet, UART1, and LCD Display devices.
The NicheLite software is contained in the file, nichelite.hex, which must be copied to the Flash memory of the STR912 processor. This can be accomplished using the RLink Debugger-Programmer device (part number STX-RLINK, from Raisonance).
When the NicheLite software is started, start-up messages are displayed in the terminal emulator window. After the board is initialized, NicheLite will attempt to obtain an network IP address using DHCP. If a DHCP Server is not available, the IP address defaults to 10.0.0.100. The IP address is displayed on the LCD Display, and may change during the DHCP negotiations.
At the end of the initialization phase, the NicheTool prompt, "INET>", is display on the terminal emulator window, and the user can enter commands to display NicheLite structure and statistics or exercise the TFTP Client module. Refer to the "Diagnostic Suite Technical Reference" document for additional information.
The HTTP Server can be accessed by setting a web browser, such as Internet Explorer or Mozilla's Firefox, to the URL: http://10.0.0.100 (or the IP address obtained from the DHCP Server).
The FTP Server can be accessed from a FTP Client application running on the Host PC. Users can log onto the FTP Server with username, "guest", and password, "guest". Any of the HTTP Server files or the "memory" files in the NicheLite Virtual File System (VFS) can be retrieved using the FTP Client commands. VFS files are read-only with the exception of the "null" file, which can accept any amount of data.
There is a one-hour limit on the execution of the software.
If the NicheLite software fails to run, please check the following:
IP Address : 10.0.0.x (or a DHCP Server is available)
Subnet Mask: 255.0.0.0
Gateway : 10.0.0.1
Serial port: 115200 baud, no parity, 1 stop, no flow control
*************************************************************************
For additional product information, please contact:
InterNiche Technologies, Inc.
51 E Campbell Avenue, Suite 160
Campbell, CA 95008
USA
Tel: + 1 408 540 1160
Fax: + 1 408 540 1161
Sales@iNiche.com
|
*************************************************************************
Thank for evaluating the Time Limited 1 hr InterNiche TCP/IP Web Server, FTP Server and Telnet Server Demo